Characteristics | Test Method | English | Metric |
Areal Weight | ASTM D5041 | 17.0 oz./sq. yd. | 575 gms./sq.m. |
Thickness | ASTM D5030 | 0.030 inches | 0.76 mm. |
Breaking Strength (lbs.) | ASTM D5100 | ||
Warp | 240 lbs. | 1067 N | |
Fill |
160 lbs. | 712 N | |
Tear Strength (lbs.) | ASTM D1424 | ||
Warp |
10 lbs. | 44 N | |
Fill |
15 lbs. | 67 N | |
Flame Resistance |
ASTM D6413 | ||
After Flame (max.) |
1.0 seconds | 1.0 seconds | |
Char Length (max.) |
1.0 inches | 2.54 cm. | |
Radiant Reflectivity (min.) | MIL-C-24929A | 20 seconds | 20 seconds |
Aluminized 100% Preox® provides the highest level of protection against molten metal splash. There is potential for flex fatigue failure of the fabric if the garment experiences heavy use. Style 1100-4 is most successful when used in a garment that is replaced often due to splash degradation.